Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent hear from the Headlights: Daytime Running Lamps (DRL) Diagnostic System Check? | -- | Go to DRL Diagnostic System Check | |
2 |
Is the voltage within the specified values? | 10.0-14.0V | ||
3 | Check the CR CONT MiniFuse® #20 for an open. Is the CR CONT MiniFuse® #20 open? | -- | ||
4 | Repair a short to the ground in CKT 1239. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
5 |
Is the voltage within the specified values? | -- | Refer to Power Distribution | |
6 | Repair a poor connection or an open in CKT 1239. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
7 |
Is the voltage within the specified values? | 10.0-14.0V | ||
8 | Check the BCM 13 MiniFuse® #6 for an open. Is the fuse open? | -- | ||
9 | Repair a short to ground in CKT 141. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
10 |
Is the voltage within the specified values? | 10.0-14.0V | Refer to Power Distribution | |
11 | Repair a poor connection or an open in CKT 141. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
12 |
Is CKT 150 continuous to ground? | -- | ||
13 | Repair an open in CKT 150 between the DRL Control Module connector C2 terminal A and G201. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
14 |
Is the voltage within the specified values? | 10.0-14.0V | ||
15 |
Is the voltage within the specified values? | 10.0-14.0V | ||
16 | Repair a short to ground in CKT 33. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
17 | Replace the Park Brake Switch. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
18 |
Is the voltage within the specified values? | 10.0-14.0V | ||
19 |
Is the voltage within the specified values? | 10.0-14.0V | Refer to Power Distribution | |
20 | Connect a fused jumper (20 A) between the instrument panel electrical center terminal A and terminal B which is used for the HDLP Circuit Breaker #53. Does the 20 A fuse within the fused jumper immediately show an open circuit? | -- | ||
21 | Repair a short to ground in CKT 842 or CKT 103. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
22 |
Is the voltage within the specified values? | 10.0-14.0V | ||
23 | Replace the HDLP Circuit Breaker #53. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
24 | Repair the open in CKT 842. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
25 |
Is the voltage within the specified values? | 10.0-14.0V | ||
26 | Replace the DRL Control Module. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
27 |
Is the voltage within the specified values? | 10.0-14.0V | ||
28 | Replace the headlamp opening door actuator control module. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
29 | Repair the open in CKT 103. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent hear from the Headlights: Daytime Running Lamps (DRL) Diagnostic System Check? | -- | Go to DRL Diagnostic System Check | |
2 | Perform the BCM Diagnostic System Check. Are any DTCs stored in memory? | -- | Go to the applicable DTC table | |
3 | Are both the LH and RH turn/park lamps inoperative during Daytime Running Lamps (DRL) operational mode? | -- | ||
4 | Is just the RH turn/park lamp inoperative during DRL operational mode? | -- | ||
5 | Is just the LH turn/park lamp inoperative during DRL operational mode? | -- | Go to DRL Diagnostic System Check | |
6 |
Is the voltage within the specified values? | 10.0-14.0V | ||
7 | Replace the instrument panel electrical center. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
8 | Connect a fused jumper (10 A) between terminals 87 and 30 of the instrument panel electrical center which is used for the DRL R Micro Relay #38. Does the RH turn/park illuminate? | -- | ||
9 |
Is the voltage within the specified values? | 10.0-14.0V | ||
10 |
Does the RH turn/park lamp illuminate? | -- | ||
11 | Replace the BCM. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
12 |
Is CKT 1915 continuous between these two terminals? | -- | ||
13 | Replace the DRL R Micro Relay #38. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
14 | Repair the open in CKT 1915. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
15 |
Is the CKT 150 continuous to ground? | -- | ||
16 | Repair an open in CKT 150 between the RH turn/park lamp socket terminal G and G102. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
17 | Replace the RH turn/park lamp. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
18 | Repair an open in CKT 1315 between the instrument panel electrical center and the RH turn/park lamp. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
19 |
Is the voltage within the specified values? | 10.0-14.0V | ||
20 | Replace the instrument panel electrical center. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
21 | Connect a fused jumper (10 A) between terminals 87 and 30 of the instrument panel electrical center which is used for the DRL L Micro Relay #40. Does the RH turn/park illuminate? | -- | ||
22 |
Is the voltage within the specified values? | 10.0-14.0V | ||
23 |
Does the LH turn/park lamp illuminate? | -- | ||
24 | Replace the BCM. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
25 |
Is CKT 1915 continuous between these two terminals? | -- | ||
26 | Replace the DRL 7 Micro Relay #40. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
27 | Repair the open in CKT 1914. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
28 |
Is the CKT 150 continuous to ground? | -- | ||
29 | Repair an open in CKT 150 between the LH turn/park lamp socket terminal G and G101. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
30 | Replace the LH turn/park lamp. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
31 | Repair an open in CKT 1314 between the instrument panel electrical center and the LH turn/park lamp. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
32 |
Is the voltage within the specified values? | 10.0-14.0V | Refer to Power Distribution | |
33 | Connect a fused jumper (20 A) between the instrument panel electrical center terminal A and terminal B which is used for the APPROACH Minifuse® #2. Does the 20 A fuse within the fused jumper immediately show an open circuit? | -- | ||
34 | Repair a short to ground in CKT 2740. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
35 |
Is the voltage within the specified values? | 10.0-14.0V | ||
36 | Replace the instrument panel electrical center. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |
37 | Repair the open in CKT 2740. Is the repair complete? | -- | Go to DRL Diagnostic System Check | -- |