Fog Lamps Inoperative
Step
| Action
| Value(s)
| Yes
| No
|
1
| Were you sent from Foglamp Diagnostic System Check.
| --
|
Go to Step 2
| Go to Foglamp Diagnostic System Check
|
2
| Perform the BCM Diagnostic System Check?
Are any DTCs stored in memory?
| --
| Go to applicable diagnostic table
|
Go to Step
3
|
3
|
- Disconnect the LH fog lamp connector.
- Connect a DMM between the LH fog lamp connector terminal B and
ground.
- Turn the ignition switch to the ON position.
- Turn the headlamps ON.
- Depress the foglamp switch button.
- Measure the voltage at the LH fog lamp connector terminal B.
Is the voltage within the specified value?
| 10.0-14.0V
|
Go to Step
28
|
Go to Step 4
|
4
| Does the front fog lamp indicator
illuminate?
| --
|
Go to Step 27
|
Go to Step
5
|
5
|
- Remove the Fog LP Micro Relay #31.
- Connect a DMM between the underhood electrical center terminal
30 (which is used for the Fog LP Micro Relay #31) and ground.
- Measure the voltage at the underhood electrical center terminal
30.
Is the voltage within the specified value?
| 10.0-14.0V
|
Go to Step
6
| Refer
to Power Distribution
|
6
| Check the FOG LP Minifuse® #6 for being open.
Is the FOG LP Minifuse® #6 open?
| --
|
Go to Step 7
|
Go to Step 8
|
7
| Repair the short to ground in CKT 34 between
the underhood electrical center connector C2 terminal D1 and the fog lamp
switch connector terminal 5 or the underhood electrical center connector C2
terminal C1/E4 and the LH/RH fog lamp.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
8
| Install a jumper wire between the FOG LP Micro Relay #31 terminals 30 and
87 in the underhood electrical center.
Do the fog lamps and the fog lamp indicator illuminate?
| --
|
Go to Step
9
|
Go to Step 12
|
9
|
- Connect the DMM between the underhood electrical center terminal
85 (which is used for the FOG LP Micro Relay #31) and ground
Measure the voltage at the underhood electrical center terminal 85.
Is the voltage within the specified values?
| 10.0-14.0V
|
Go to Step
9
| Refer
to Power Distribution
|
10
|
- Disconnect the BCM connector C1.
- Connect a DMM between the underhood electrical center terminal
86 (which is used for the FOG LP Micro Relay #31) and the BCM connector C1
terminal B4.
- Measure the resistance between the underhood electrical center
terminal 86 and the BCM connector C1 terminal B4.
Is the resistance within the specified values?
| 0-3ohms
|
Go to Step
13
|
Go to Step 11
|
11
| Repair the open in CKT 1317.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
12
| Repair the open in CKT 34 between:
• | the underhood electrical center connector C2 terminal D1 and the
fog lamp switch connector terminal 5 |
• | the underhood electrical center connector C3 terminal C1 and the
LH fog lamp. |
• | the underhood electrical center connector C3 terminal E4 and the
RH fog lamp. |
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
13
|
- Reinstall the FOG LP Micro Relay #31 into the underhood electrical
center.
- Install a fused jumper (10 A) between the BCM connector C1 terminal
B4 and ground.
Do the fog lamps and the fog lamp indicator illuminate?
| --
|
Go to Step
15
|
Go to Step 14
|
14
| Replace FOG LP Micro Relay
#31.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
15
|
- Disconnect the fog lamp/rear compartment lid release switch (domestic)
or the fog lamp switch (export) connector.
- Connect a DMM between the fog lamp/rear compartment lid release
switch (domestic) or the fog lamp switch (export) connector terminal 1 and
ground.
- Measure the voltage at the fog lamp/rear compartment lid release
switch (domestic) or the fog lamp switch (export) connector terminal 1.
Is the voltage within the specified value?
| 10.0-14.0V
|
Go to Step
22
|
Go to Step 16
|
16
| Check the F/TNK DR Minifuse®
#32 for an open.
Is the fuse open?
| --
|
Go to Step 18
|
Go to Step 17
|
17
|
- Remove the F/TNK DR Minifuse® #32.
- Connect a DMM between the instrument panel electrical center terminal
A (which is used for the F/TNK DR Minifuse® #32) and ground.
- Measure the voltage at instrument panel electrical center terminal
A.
Is the voltage within the specified values?
| 10.0-14.0V
|
Go to Step
19
| Refer
to Power Distribution
|
18
|
- Remove the F/TNK DR Minifuse® #32.
- Leave the fog lamp/rear compartment lid release switch (domestic)
or the fog lamp switch (export) still disconnected.
- Connect a DMM between the instrument panel electrical center terminal
B (which is used for the F/TNK DR Minifuse® #32) and ground.
- Measure the resistance between the instrument panel electrical
center terminal B and ground.
Is the resistance within the specified values?
| 0-3ohms
|
Go to Step
20
|
Go to Step 21
|
19
| Repair the open in CKT 2840.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
20
| Repair the short to ground in CKT 2840.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
21
| Repair the short to ground in CKT 192.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
22
|
- Disconnect the BCM Connector C2.
- Connect a DMM between the BCM connector C2 terminal D4 and the
fog lamp/rear compartment lid release switch (domestic) or the fog lamp switch
(export) connector terminal 2.
- Measure the resistance between the BCM connector C2 terminal D4
and the fog lamp/rear compartment lid release switch (domestic) or the fog
lamp switch (export) connector terminal 2.
Is the resistance within the specified values?
| 0-3ohms
|
Go to Step
23
|
Go to Step 24
|
23
|
- Reconnect the fog lamp/rear compartment lid release switch (domestic)
or the fog lamp switch (export) connector.
- Connect a DMM between the BCM connector C2 terminal D4 and ground.
- Press the fog lamp/rear compartment lid release switch (domestic)
or the fog lamp switch (export) button.
- Measure the voltage at the BCM connector C2 terminal D4 with the
fog lamp/rear compartment lid release switch (domestic) or the fog lamp switch
(export) button depressed.
Is the voltage within the specified values?
| 10.0-14.0V
|
Go to Step
25
|
Go to Step 26
|
24
| Repair the open in CKT 192.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
25
| Replace the BCM.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
26
| Replace the fog lamp/rear compartment lid release switch (domestic)
or the fog lamp switch (export).
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
27
|
- Disconnect the LH/RH foglamp connectors.
- Connect a DMM between the LH/RH foglamp connector terminal B and:
• | the underhood electrical center connector C3 terminal C1. |
• | the underhood electrical center connector C3 terminal E4 |
- Measure the resistance between the underhood electrical center
connector C3 terminals C1/E4 and the LH/RH foglamp connectors.
Is the resistance within the specified values?
| 0-3ohms
|
Go to Step
32
|
Go to Step 31
|
28
|
- Disconnect the LH/RH foglamp connectors.
- Connect a DMM between the LH/RH foglamp connector terminal A and
ground.
- Measure the resistance between the LH/RH foglamp connector terminal
A and ground.
Is the resistance within the specified values?
| 0-3ohms
|
Go to Step
30
|
Go to Step 29
|
29
| Repair the open in CKT 150
between the foglamp connector and G102.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
30
| Replace the inoperative foglamp bulb.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
31
| Repair the open in CKT 34.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|
32
| Replace the underhood electrical center.
Is the repair complete?
| --
| Go
to Foglamp Diagnostic System Check
| --
|