Hazard Lamps Inop/Turn Lamps Work

Step

Action

Value(s)

Yes

No

1

Were you sent here from the Exterior Lights Diagnostic System Check?

--

Go to Step 2

Go to Exterior Lights Diagnostic System Check

2

  1. Disconnect the hazard warning switch connector.
  2. Connect a DMM between the hazard warning switch connector terminal B and ground.
  3. Measure the voltage available at the connector.

Is the voltage within the specified values?

10.0-14.0V

Go to Step 6

Go to Step 3

3

Check the STP/HAZ MiniFuse® #8 for an open circuit.

Is the fuse open?

--

Go to Step 4

Go to Step 5

4

Repair a short to ground in CKT 140.

Is the repair complete?

--

Go to Exterior Lights Diagnostic System Check

--

5

Repair a poor connection or an open in CKT 140.

Is the repair complete?

--

Go to Exterior Lights Diagnostic System Check

--

6

  1. Disconnect the connector C209.
  2. Connect a DMM between the hazard warning switch connector terminal J and connector C209 terminal A.
  3. Measure CKT 27 for continuity between these two connector terminals.

Is continuity present in CKT 27 between these two connectors?

--

Go to Step 8

Go to Step 7

7

Repair the open in CKT 27.

Is the repair complete?

--

Go to Exterior Lights Diagnostic System Check

--

8

  1. Reconnect the hazard warning switch connector.
  2. Connect a DMM between the connector C209 terminal A and ground.
  3. Measure the available voltage at C209 terminal A.

Is the voltage within the specified values?

10.0-14.0V

Go to Step 10

Go to Step 9

9

Replace the hazard warning switch .

Is the repair complete?

--

Go to Exterior Lights Diagnostic System Check

--

10

Replace the turn signal switch.

Is the repair complete?

--

Go to Exterior Lights Diagnostic System Check

--