Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the Interior Lights Dimming Diagnostic System Check | Go To Interior Lights Dimming Diagnostic System Check | ||
2 |
Is the voltage within the specified values? | 10.0-14.0V | ||
3 |
Does the light inside the PRNDL illuminate? | -- | ||
4 | Check the PKT/LP MiniFuse® #6 for an open. Is the fuse open? | -- | ||
5 | Repair an open in the CKT 240. Is the repair complete? | -- | Go To Interior Lights Dimming Diagnostic System Check | -- |
6 | Repair a short to ground in CKT 240. Is the repair complete? | -- | Go To Interior Lights Dimming Diagnostic System Check | -- |
7 | Replace the BCM. Is the repair complete? | -- | Go To Interior Lights Dimming Diagnostic System Check | -- |
8 |
Is CKT 8 continuous between the BTSI Control Solenoid connector and the BCM connector C3? | -- | ||
9 | Repair an open in the CKT 8. Is the repair complete? | -- | Go To Interior Lights Dimming Diagnostic System Check | -- |
10 | Replace the PRNDL illumination lamp. Is the repair complete? | -- | Go To Interior Lights Dimming Diagnostic System Check | -- |