RAP Remains ON with LH Door Open
Step
| Action
| Value(s)
| Yes
| No
|
1
| Were you sent here from the RAP Diagnostic System Check?
| |
Go to Step
2
| Go to
Retained Accessory Power (RAP) System Check
|
2
|
- Install the scan tool.
- Establish communication with the LH door control module.
Can communication be established?
| --
| Refer to Scan Tool does not communicate w/class 2 Data Line
|
Go to Step 3
|
3
| Check for any DTCs present.
Are any DTCs present?
| | Refer to applicable DTC
diagnostic table
|
Go to Step 4
|
4
|
- Disconnect the LH door control module connector C1.
- Open the LH door.
- Use the DMM to measure the resistance between terminal 10 of the
LH door control module connector C1 and ground.
Is the resistance within the specified range?
| Less than 2 ohms
|
Go to Step
10
|
Go to Step 5
|
5
|
- Disconnect the LH door ajar indicator switch.
- Use the DMM to measure the resistance between terminal B of the
LH door ajar indicator switch connector and terminal 10 of the LH door control
module connector.
Is the resistance within the specified range?
| Less than 2 ohms
|
Go to Step
7
|
Go to Step 6
|
6
| Locate and repair an open or
a high resistance in CKT 745.
Is the repair complete?
| --
| Go
to
Retained Accessory Power (RAP) System Check
| --
|
7
| Use the DMM to measure
the resistance between terminal D of the LH door ajar indicator switch connector
and ground.
Is the resistance within the specified range?
| Less than 2 ohms
|
Go to Step
9
|
Go to Step 8
|
8
|
- Locate and repair an open or a high resistance in CKT 150.
- If CKT 150 is OK, replace the splice pack #S201 (SP201).
Is the repair complete?
| --
| Go
to
Retained Accessory Power (RAP) System Check
| --
|
9
| Replace the LH door
ajar indicator switch.
Is the replacement complete?
| --
| Go
to
Retained Accessory Power (RAP) System Check
| --
|
10
|
- Disconnect the BCM connector C2.
- Use the DMM to measure the resistance between terminal C2 of the
BCM connector C2 and ground.
Is the resistance within the specified range?
| Less than 2 ohms
| Go to
Retained Accessory Power (RAP) System Check
|
Go to Step 11
|
11
| Locate and repair an open or
a high resistance in CKT 745.
Is the repair complete?
| --
| Go
to
Retained Accessory Power (RAP) System Check
| --
|