GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 63701  Size: SH
  1. Remove the bolts attaching the close out panel to the wheelhouse panel.
  2. Remove the bolts attaching the close out panel to the fascia.
  3. Remove the close out panel.

Installation Procedure


    Object Number: 63701  Size: SH
  1. Position the close out panel to the wheelhouse panel and to the fascia.
  2. Install the bolts attaching the close out panel to the fascia.
  3. Install the bolts attaching the close out panel to the wheelhouse panel.
  4. Tighten
    Tighten the fascia close out panel bolts to 7 N·m (62 lb in).

    Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.