Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is the voltage within specified range? | 10.0-14.0V | ||
2 | Replace the right Door Control Module (DCM). Is the repair completed? | Recheck the System Operation | ||
3 |
Is the voltage within specified range? | 10.0-14.0V | ||
4 | Repair the open in CKT 2340, between the connector C200 terminal C and the right Door Control Module (DCM) connector C1 terminal 1. Is the repair complete? | Recheck the System Operation | ||
5 |
Is the voltage within the specified range? | 10.0-14.0V | ||
6 | Repair the open in CKT 2340, between the connector C200 terminal C and the instrument panel electrical center connector C1 terminal C11. Is the repair complete? | Recheck the System Operation | ||
7 | Replace the instrument panel electrical center. Is the repair completed? | Recheck the System Operation |