Removal Procedure
- Remove the service port
valve caps.
- Recover the refrigerant. Refer to Refrigerant Recovery and Recharging
.
- Using an R-134a valve core remover/installer, unscrew and remove
the valve core from the service port.
Installation Procedure
- Using an R-134a valve
core remover/installer,
install the new valve core to the service port.
- Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging
.
- Check the service ports for refrigerant leaks. Refer to Leak Testing
.
- Install the service port valve caps.