Removal Procedure
Caution: Unplug the blower motor before removal. Blower motor case contact with any ground
may start the fan and cause personal injury.
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect the negative battery cable.
- Remove the I/P lower insulator panel - RH.
Refer to
Instrument Panel Insulator Panel Replacement
in Instrument Panel, Gauges
and Console.
- Disconnect the blower motor control module electrical connector
from the blower motor.
- Disconnect the blower motor cooling tube
from the HVAC module.
- Remove the three blower motor retaining screws.
- Remove the blower motor with fan from the HVAC module.
Installation Procedure
- Install the blower motor with fan to
the HVAC module.
- Install the blower motor retaining screws.
Tighten
Tighten the blower motor retaining screws to 1.7 N·m (15 lb in).
- Connect the blower motor cooling tube to the HVAC module.
- Connect the blower motor control module
electrical connector to the blower motor.
- Install the I/P lower insulator panel - RH.
Refer to
Instrument Panel Insulator Panel Replacement
in Instrument Panel, Gauges
and Console.
- Connect the negative battery cable.
Tighten
Tighten the negative battery cable bolt to 15 N·m (11 lb ft).
- Program the transmitters. Refer to
Transmitter Programming/Synchronization
in Keyless Entry.