Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent hear from the DRL System Check? | -- | Go to DRL System Check | |
2 | Are just the park/marker lamps inoperative during low light conditions? | -- | ||
3 | Are just the LH turn signal lamps inoperative during low light conditions? | -- | ||
4 | Are just the RH turn signal lamps inoperative during low light conditions? | -- | ||
5 | Are both the park/marker lamps and turn signal lamps inoperative during low light conditions? | -- | System OK | |
6 |
Do the park/marker lamps and turn signal lamps illuminate? | -- | ||
7 |
Is continuity present between terminal G and terminal H? | -- | ||
8 | Replace the DRL ambient light sensor. Is the repair complete? | -- | Go to DRL System Check | -- |
9 |
Is continuity present between terminal G and ground? | -- | ||
10 | Repair a short to ground in CKT 1137. Is the repair complete? | -- | Go to DRL System Check | -- |
11 |
Is continuity present between terminal H and ground? | -- | ||
12 | Repair a short to ground in CKT 1138. Is the repair complete? | -- | Go to DRL System Check | -- |
13 |
Is continuity present between the DRL ambient light sensor connector terminal A and the DRL control module connector C2 terminal H? | -- | ||
14 |
Is continuity present between the DRL ambient light sensor connector terminal B and the DRL control module connector C2 terminal G? | -- | ||
15 | Repair an open in CKT 1138. Is the repair complete? | -- | Go to DRL System Check | -- |
16 | Repair an open in CKT 1137. Is the repair complete? | -- | Go to DRL System Check | -- |
17 | Replace the DRL control module. Is the repair complete? | -- | Go to DRL System Check | -- |
18 |
Is the voltage within the specified values? | 10.0-14.0V | ||
19 | Check the PKT/LP MiniFuse® #6. Is the fuse open? | -- | ||
20 | Insert a new PKT/LP MiniFuse® #6. Does the new fuse open immediately? | -- | ||
21 | Repair a short to ground in CKT 240. Is the repair complete? | -- | Go to DRL System Check | -- |
22 | Repair an open in CKT 240. Is the repair complete? | -- | Go to DRL System Check | -- |
23 | Connect a fused jumper (10 A) between the DRL connector C1 terminal A and connector C1 terminal H. Does the fused jumper or the PKT/LP MiniFuse® #6 open immediately? | -- | ||
24 | Repair a short to ground in CKT 9. Is the repair complete? | -- | Go to DRL System Check | -- |
25 | With the fused jumper (10 A) in place, are the rear park/marker lamps illuminated? | -- | ||
26 | Repair the open in CKT 9 between the DRL control module and the underhood electrical center. Is the repair complete? | -- | Go to DRL System Check | -- |
27 | Replace the DRL control module. Is the repair complete? | -- | Go to DRL System Check | -- |
28 |
Is the voltage within the specified values? | 10.0-14.0V | ||
29 | Check the CR CONT MiniFuse® #20. Is the fuse open? | -- | ||
30 | Insert a new CR CONT MiniFuse® #20. Does the new fuse open immediately? | -- | ||
31 | Repair a short to ground in CKT 1239. Is the repair complete? | -- | Go to DRL System Check | -- |
32 | Repair an open in CKT 1239. Is the repair complete? | -- | Go to DRL System Check | -- |
33 | Connect a fused jumper (10 A) between the DRL connector C2 terminal C and connector C1 terminal B. Does the fused jumper or the CR CONT MiniFuse® #6 open immediately? | -- | ||
34 |
Does the 10 A fuse within the fused jumper or the CR CONT MiniFuse® #20 open immediately? | -- | ||
35 | Repair a short to ground in CKT 1414. Is the repair complete? | -- | Go to DRL System Check | -- |
36 |
Is the CKT 1314 continuous to ground? | -- | ||
37 | Replace the DRL L Micro Relay. Is the repair complete? | -- | Go to DRL System Check | -- |
38 | Repair a short to ground in CKT 1314. Is the repair complete? | -- | Go to DRL System Check | -- |
39 | With the fused jumper (10 A) in place, does the LH front turn signal lamp illuminate? | -- | ||
40 | Replace the DRL control module. Is the repair complete? | -- | Go to DRL System Check | -- |
41 |
Does the LH front turn signal lamp illuminate? | -- | ||
42 |
Is the CKT 150 continuous to ground? | -- | ||
43 | Repair an open in CKT 150 between the LH turn signal lamp socket terminal G and G102. Is the repair complete? | -- | Go to DRL System Check | -- |
44 | Replace the LH turn signal lamp bulb. Does the new bulb illuminate? | -- | Go to DRL System Check | |
45 | Replace the DRL L Micro Relay. Is the repair complete? | -- | Go to DRL System Check | -- |
46 | Repair the open in CKT 1314. Is the repair complete? | -- | Go to DRL System Check | -- |
47 |
Is the voltage within the specified values? | 10.0-14.0V | ||
48 | Check the CR CONT MiniFuse® #20. Is the fuse open? | -- | ||
49 | Insert a new CR CONT MiniFuse® #20. Does the new fuse open immediately? | -- | ||
50 | Repair a short to ground in CKT 1239. Is the repair complete? | -- | Go to DRL System Check | -- |
51 | Repair an open in CKT 1239. Is the repair complete? | -- | Go to DRL System Check | -- |
52 | Connect a fused jumper (10 A) between the DRL connector C2 terminal C and connector C1 terminal C. Does the fused jumper or the CR CONT MiniFuse® #6 open immediately? | -- | ||
53 |
Does the 10 A fuse within the fused jumper or the CR CONT MiniFuse® #20 open immediately? | -- | ||
54 | Repair a short to ground in CKT 1415. Is the repair complete? | -- | Go to DRL System Check | -- |
55 |
Is the CKT 1315 continuous to ground? | -- | ||
56 | Replace the DRL R Micro Relay. Is the repair complete? | -- | Go to DRL System Check | -- |
57 | Repair a short to ground in CKT 1315. Is the repair complete? | -- | Go to DRL System Check | -- |
58 | With the fused jumper (10 A) in place, does the RH front turn signal lamp illuminate? | -- | ||
59 | Replace the DRL control module. Is the repair complete? | -- | Go to DRL System Check | -- |
60 |
Does the RH front turn signal lamp illuminate? | -- | ||
61 |
Is the CKT 150 continuous to ground? | -- | ||
62 | Repair an open in CKT 150 between the RH turn signal lamp socket terminal G and G102. Is the repair complete? | -- | Go to DRL System Check | -- |
63 | Replace the RH turn signal lamp bulb. Does the new bulb illuminate? | -- | Go to DRL System Check | |
64 | Replace the DRL R Micro Relay. Is the repair complete? | -- | Go to DRL System Check | -- |
65 | Repair the open in CKT 1315. Is the repair complete? | -- | Go to DRL System Check | -- |