Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the Exterior Lights System Check? | -- | Go to Exterior Lights System Check | |
2 | Using a scan tool, check for either DTC B2578 or B2583 stored in the BCM memory. Are either of these codes stored in memory? | -- | Go to applicable diagnostic table | |
3 |
Is the voltage within the specified values? | 10.0-14.0V | ||
4 | Check the HAZ T/SG MiniFuse® #15 for an open circuit. Is the fuse open? | -- | ||
5 | Repair a short to ground in CKT 1739. Is the repair complete? | -- | Go to Exterior Lights System Check | -- |
6 | Repair a poor connection or an open in CKT 1739. Is the repair complete? | -- | Go to Exterior Lights System Check | -- |
7 |
Is continuity present in CKT 16 between these two connectors? | -- | ||
8 | Repair the open in CKT 16. Is the repair complete? | -- | Go to Exterior Lights System Check | -- |
9 |
Is the voltage within the specified values? | 10.0-14.0V | ||
10 | Replace the hazard warning switch . Is the repair complete? | -- | Go to Exterior Lights System Check | -- |
11 | Replace the turn signal switch. Is the repair complete? | -- | Go to Exterior Lights System Check | -- |