Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the RAP Diagnostic System Check? | -- | Go to RAP Diagnostic System Check | |
2 |
Can communication be established? | -- | Refer to Scan Tool does not communicate with Component | |
3 | Check for any stored DTCs. Are any DTCs present? | -- | Refer to applicable DTC diagnostic table | |
4 |
Is CKT 745 continuous to ground? | -- | ||
5 |
Is CKT 745 continuous between these two connectors? | -- | ||
6 | Locate and repair an open or a high resistance in CKT 745. Is the repair complete? | -- | Go to RAP Diagnostic System Check | -- |
7 | Use the DMM to measure CKT 150 for continuity between terminal D of the LH door ajar indicator switch connector and ground. Is CKT 150 continuous to ground? | -- | ||
8 | Locate and repair an open or a high resistance in CKT 150. Is the repair complete? | -- | Go to RAP Diagnostic System Check | -- |
9 | Replace the LH door ajar indicator switch. Is the replacement complete? | -- | Go to RAP Diagnostic System Check | -- |
10 |
Is CKT 745 continuous to ground? | -- | ||
11 | Locate and repair an open or a high resistance in CKT 745. Is the repair complete? | -- | Go to RAP Diagnostic System Check | -- |
12 | Replace the LH door control module. Is the replacement complete? | -- | Go to RAP Diagnostic System Check | -- |