Compressor Leak Testing V7 - Direct Mount
Tools Required
• | J 43600 ACR
2000 Air Conditioning Service Center |
• | J 39893 Pressure
Testing Connector |
- With the sealing washers in place, install the J 39893
on the rear head of the A/C compressor.
- Connect the gage charging lines and the J 43600
.
- Pressurize the suction and the high-side of the A/C compressor
with R-134a refrigerant.
- With the A/C compressor in a horizontal position, rotate by hand
the A/C compressor shaft in the operating direction.
- Rotate the shaft several times.
- Using the J 39400
, check for leaks at the following locations:
6.1. | Pressure relief valve |
6.5. | Through bolt head gaskets |
6.6. | A/C compressor shaft seal |
- Perform the measures necessary to correct any external leaks found.
- Recheck for leaks following any repair.
- Recover the refrigerant.
- Disconnect the hoses from the J 39893
.
- Remove the J 39893
.