Removal Procedure
- Disassemble the A/C refrigerant components. Refer to the appropriate
repair procedure
- Remove the O-ring seal from the A/C refrigerant component.
- Inspect the O-ring seal for signs of damage.
- Inspect the A/C refrigerant components for damage or burrs. Repair if
necessary.
- Discard the O-ring seal.
Installation Procedure
- Inspect the new O-ring seal for any sign or cracks, cuts, or damage.
Replace if necessary.
- Using a lint-free clean, dry cloth, carefully clean the sealing surfaces
of the A/C refrigerant components.
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant oil
on the new O-ring seal to enter the refrigerant system.
- Lightly coat the new O-ring seal with mineral base 525 viscosity refrigerant
oil.
Important: DO NOT reuse O-ring seals.
- Carefully slide the new O-ring seal onto the A/C refrigerant component.
- The O-ring seal must be fully seated.
- Assemble the A/C components.