Removal Procedure
- Remove the I/P upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gages
and Console.
- Remove the DRL and sunload temperature sensor wire retainers from the
windshield defroster duct.
- Remove the windshield defroster duct retaining screws.
- Release the windshield defroster duct from the LH and RH side window
lower defogger outlet ducts.
Lift the windshield defroster duct slightly, then use a twisting motion to
release from the side window lower defogger ducts.
- Remove the defroster duct.
Installation Procedure
- Install the defroster duct.
Use a twisting motion to secure the windshield defroster duct to the LH and
RH side window lower defogger outlet ducts.
- Lower the windshield defroster duct into position and align the duct
with the opening of the HVAC module and the I/P upper support beam.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the windshield defroster duct LH retaining screw first (net location),
then install the RH retaining screw.
Tighten
Tighten the screws to 10 N·m (89 lb in).
- Install the DRL and sunload temperature sensor wire retainers to the
windshield defroster duct.
- Install the I/P upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in Instrument Panel, Gages
and Console.