GM Service Manual Online
For 1990-2009 cars only
Table 1: Body Control Module (BCM) Scan Tool Data List
Table 2: Heating and Air Conditioning Scan Tool Data List
Table 3: PCM Scan Tool Data List

Use the Scan Tool Data Display Values and Definitions Information in order to assist in diagnosing the Instrument Panel Integration Module (IPM) problems. Compare the vehicles actual scan tool data with the typical data display value table information. Use the data information in order to aid in understanding the nature of the problem when the vehicle does not match with the typical data display values.

The scan tool data values were taken from a known good vehicle under the following conditions:

    • The ignition switch is in the ON position.
    • The engine is running at idle.
    • The vehicle is in PARK.
    • The doors are closed.
    • The windows are closed.
    • The A/C is ON.
    • The ambient air temperatures are at 22-27°C (70-80°F).

Body Control Module (BCM) Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)

HVAC Bulb Illumination

Data

Percentage

15-99%

Heating and Air Conditioning Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)

A/C Button

Inputs

On/Off

Off

Auto Button

Inputs

On/Off

Off

Calibration ID

Module Information

8-digit alphanumeric

AE017509

Desired Blower Mtr Speed

Data

Counts

15-111 Counts

Driver Temp Dial

Data

°C/°F

15- 31°C/59-89°F

Fan Down Button

Inputs

Off/On

Off

Fan Up Button

Inputs

Off/On

Off

Front Defrost Button

Inputs

Off/On

Off

Inside Temp Sensor

Data

Volts

2.3Volts

LH Mix Mtr Position Feedback

Data

Counts

3-252 Counts

LH Mix Mtr Position Requested

Data

Counts

1-254 Counts

Mix Motor State

Data

Normal/Fault

Normal

Mode Button

Inputs

Off/On

Off

Off Button

Inputs

Off/On

Off

Outside Air Button

Inputs

Off/On

Off

Outside Temp Sensor

Data

Volts

1.7 Volts

Passenger Temp Dial

Data

Counts

26-80 Counts

Rear Defrost Button

Inputs

Off/On

Off

Recirculate Button

Inputs

Off/On

Off

RH Mix Mtr Position Feedback

Data

Counts

22-251 Counts

RH Mix Mtr Position Requested

Data

Counts

1-254 Counts

Rom ID

Module Information

8-digit alphanumeric

AE017414

ROM Part Number

Module Information

6-digit alphanumeric

8F2259

Sun Load Sensor

Data

Volts

4.3 Volts

Vacuum Solenoid 1

Data

Off/On

varies

Vacuum Solenoid 2

Data

Off/On

varies

Vacuum Solenoid 3

Data

Off/On

varies

Vacuum Solenoid 4

Data

Off/On

varies

Vacuum Solenoid 5

Data

Off/On

varies

PCM Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)

A/C High Side Pressure

Engine Data 2

kPa/psi

965 kPa/140 psi

A/C High Side Pressure

Engine Data 2

Volts

1.65 Volts

A/C Relay Command

Engine Data 1/Engine Data 2/Misfire Data

On/Off

On

A/C Request Signal

Engine Data 1/Engine Data 2/Enhanced EVAP Data

Yes/No

Yes

A/C Clutch Feedback Signal

Engine Data 2

On/Off

On