Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Master Electrical Component List | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 | Place the hazard switch to the ON position. Do the hazard lamps turn ON? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 4 |
4 | Repair the open, high resistance, or short to ground in the STP HAZ circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 6 | -- |
5 | Replace the hazard warning switch. Refer to Hazard Warning Switch Replacement . Is the repair complete? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |