The backup lamp circuit is part of a standard backup lamp system except for the addition of a relay and the BCM providing a control circuit. The BCMcan ground the backup lamp relay control circuit in order to energize the relay and turn ON the backup lamps, allowing the lamps to be used for the Universal Theft Deterrent (UTD) and approach lighting functions. The BCMmonitors the voltage level on the backup lamp control circuit. When theBCM commands the relay ON, the voltage level on the control circuit shouldbe low. When the relay is OFF, the voltage level should be high. If theBCM detects a voltage level other than expected, a malfunction is presentand a DTC will set.
• | The BCM detects a high voltage level (a short to voltage or BCM open internally) in the backup lamp relay control circuit. |
• | The BCM can only test for this condition with the backup lamp relay energized. |
• | All conditions must be present for 2 seconds. |
Stores a DTC B2483 in the BCM memory.
• | This DTC requires an ignition cycle in order to change from current to history. |
• | The BCM no longer detects a high voltage level in the backup lamp relay control circuit only with the backup lamp relay energized. |
• | A history DTC will clear after 50 consecutive ignition cycles if the condition for the malfunction is no longer present. |
• | Use the IPC clearing DTCs feature. |
• | The BCM receives the Clear Code command from the scan tool. |
• | The following conditions may cause an intermittent malfunction: |
- | There is an intermittent short to battery positive voltage in the backup lamp relay control circuit. |
- | There is low resistance in the relay coil. |
- | There are poor connections at the BCM, the underhood fuse center, or the backup lamp relay terminals. |
- | The backup lamp relay is shorted to battery positive voltage internally. |
• | If the BCM is open internally, or if the backup lamp relay control circuit is shorted to voltage BCM cannot provide output control for the backuplamps for UTD and approach lighting functions, but standard backup lamp functionswill still operate normally. |
• | If the DTC is a history DTC, the problem may be intermittent. Perform the tests shown while moving related wiring and connectors. This canoften cause the malfunction to occur. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
The number(s) below refer to the step number(s) on the diagnostic table.
Listen for an audible click when the backup lamp relay operates. Command both the ON andOFF states. Repeat the commands as necessary.
Tests for voltage at the coil side of the backup lamp relay. The APPROACH fuse supplies powerto the coil side of the backup lamp relay.
Verifies that the BCM is providing ground to the backup lamp relay.
Tests if ground is constantly being applied to the backup lamp relay.
Tests for a short to battery positive voltage in the Backup Lamp control circuit.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Master Electrical Component List | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
Does the backup lamp relay turn ON and OFF with each command? | Go to Diagnostic Aids | Go to Step 3 | |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 10 | |
Does the test lamp turn ON and OFF with each command? | Go to Step 8 | Go to Step 5 | |
Does the test lamp remain illuminated with each command? | Go to Step 7 | Go to Step 6 | |
Test the control circuit of the backup lamp relay for a short to battery positive voltage.Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 9 | |
7 | Test the control circuit of the backup lamp relay for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
8 | Inspect for poor connections at the backup lamp relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the BCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
10 | Repair the coil side supply circuit of the backup lamp relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
11 | Replace the backup lamp relay. Refer to Relay Replacement in Wiring Systems. Did you complete the replacement? | Go to Step 13 | -- |
12 |
Important: Perform the BCM reprogram procedure. Refer to Body Control Module (BCM) Programming/RPO Configuration in Body Control System. Replace the BCM. Refer to Body Control Module Replacement in Body Control System. Did you complete the replacement? | Go to Step 13 | -- |
13 |
Does the DTC reset? | Go to Step 2 | System OK |