Removal Procedure
- Turn the ignition switch to the OFF position.
- Disconnect the EBCM harness connector.
- Remove the two insulator nuts (1).
- Lift the EBCM/BPMV out of the bracket high enough to allow clearance
to remove the insulator mounting bolt and the EBCM.
- Remove the insulator mounting bolt from the EBCM.
- Remove the six EBCM to BPMV bolts.
- Separate the EBCM from the BPMV by gently pulling apart until separated.
- Carefully remove the seal.
The seal may by reused if it is
not cut or damaged.
Installation Procedure
- Clean the BPMV seal surface with alcohol
using a clean rag.
- Install the seal to the BPMV if it is not cut or damaged.
- Install the EBCM to the BPMV.
Notice: Refer to Fastener Notice in the Preface section.
- Tighten the six mounting bolts in the following sequence:
Tighten
• | First pass to 3 N·m (27 lb in). |
• | Second pass to 6 N·m (53 lb in). |
Important: If the insulator nut was removed it must
be replaced with a new insulator nut.
- Install the front EBCM insulator mounting bolt.
Tighten
Tighten the bolt to 14 N·m (10 lb ft).
- Install the EBCM/BPMV into the bracket.
- Install the two insulator nuts (1).
Tighten
Tighten the two insulator nuts to 12 N·m
(106 lb in).
- Connect the EBCM harness connector.
Important: Both sides of the EBCM harness connector
must be engaged with lever before closing.
- Turn the ignition switch to the ON position; do NOT start the engine.
- Perform the
Diagnostic System Check - ABS
.