Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Head Up Display Schematics | |||
1 | Did you perform the IPC Diagnostic System Check? | Go to Step 2 | |
2 | Verify the hazard indicators HUD display are operating properly. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 |
4 | Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement? | Go to Step 7 | -- |
5 |
Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
6 | Replace the hazard warning switch. Refer to Hazard Warning Switch Replacement in Lighting Systems. Did you complete the replacement? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |