• | Complete the check list, prior to performing the diagnosis: |
- | When the folding top control switch is pressed, check for driver information center (DIC) warning messages. |
- | Windows are normalized. Refer to Power Windows Description and Operation . |
- | Luggage barrier is installed and secured, closing the luggage barrier switch. |
- | Vehicle is in PARK or the park brake is applied with manual transmission. |
- | Press the ignition to ACCY or RUN, with the engine OFF. |
- | Hydraulic fluid bypass valve in the operating position, turned clockwise, located above the pump motor. |
- | Operating temperature is normal. |
• | When using the scan tool, the folding top cover is referenced as the tonneau. |
• | If a repair is made to a signal circuit for a fault to ground, test the component of that circuit for proper operation. |
• | Using the scan tool to access the History parameters for the folding top control (FTC) module, will display the last status of the items listed. |
The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Folding Top Schematics Connector End View Reference: Power Roof Systems Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 | Verify that the Power Folding Top Does Not Close complaint is present. Does the power folding top close as described in the system description and operation? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Press the folding top close control switch. Did the folding top cover latch actuator release? | Go to Step 4 | Go to Folding Top Stowage Compartment Lid Release Inoperative |
4 | Did the folding top cover raise to the open position? | Go to Step 5 | |
5 | While the folding top cover was raising to the open position, did the folding top cover pull down striker extend to the up position? | Go to Step 6 | Go to Folding Top Stowage Compartment Lid Release Inoperative |
6 | During the folding top close operation, did top movement stop after the folding top cover opened? | Go to Step 13 | Go to Step 7 |
7 | During the folding top close operation, did top movement stop after the folding top raised to the up position? | Go to Step 16 | Go to Step 8 |
8 | During the folding top close operation, did top movement stop after the 5 bow raised? | Go to Step 19 | Go to Step 9 |
9 | During the power folding top close operation, did top movement stop after the folding top cover closed? | Go to Step 10 | Go to Step 11 |
10 |
Important: Ensure that the folding top cover is latched before continuing with this diagnostic procedure. After the folding top cover closed and latched, did the folding top cover pull down retract to the down position? | Go to Step 39 | Go to Folding Top Stowage Compartment Lid Release Inoperative |
11 | During the power folding top close operation, did the 1 bow lower down onto the windshield? | Go to Step 12 | Go to Step 24 |
12 | Could an audible chime be heard after the completion of the top closed function? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 27 |
13 | With a scan tool, observe the Tonneau Open Limit Switch parameter in the Folding Top Module Inputs data list. Does the Tonneau Open Limit Switch parameter display Active? | Go to Step 22 | Go to Step 14 |
14 |
Does the test lamp illuminate? | Go to Step 15 | Go to Step 42 |
15 |
Does the Tonneau Open Limit Switch parameter display Active? | Go to Step 38 | Go to Step 34 |
16 | With a scan tool, observe the Top Closed Limit Switch parameter in the Folding Top Module Inputs data list. Does the Top Closed Limit Switch parameter display Active? | Go to Step 39 | Go to Step 17 |
17 |
Does the test lamp illuminate? | Go to Step 18 | Go to Step 42 |
18 |
Does the Top Closed Limit Switch parameter display Active? | Go to Step 37 | Go to Step 35 |
19 | With a scan tool, observe the 5 Bow Raised Pos. Switch parameter in the Folding Top Module Inputs data list. Does the 5 Bow Raised Pos. Switch parameter display Active? | Go to Step 22 | Go to Step 20 |
20 |
Does the test lamp illuminate? | Go to Step 21 | Go to Step 42 |
21 |
Does the 5 Bow Raised Pos. Switch parameter display Active? | Go to Step 37 | Go to Step 30 |
22 | With a scan tool, observe the Power Pull Down Ajar Status parameter in the Folding Top Module Inputs data list. Does the Power Pull Down Ajar Status parameter display Ajar? | Go to Step 39 | Go to Step 23 |
23 |
Does the Power Pull Down Ajar Status parameter display Ajar? | Go to Folding Top Stowage Compartment Lid Release Inoperative | Go to Step 33 |
Can an audible click be heard from the valve when it is commanded ON? | Go to Step 48 | Go to Step 25 | |
25 |
Does the test lamp illuminate when the valve is commanded ON? | Go to Step 26 | Go to Step 32 |
26 |
Does the test lamp illuminate when the valve is commanded ON? | Go to Step 41 | Go to Step 43 |
27 | With a scan tool, observe the 5 Bow Lowered Pos. Switch parameter in the Folding Top Module Inputs data list. Does the 5 Bow Lowered Pos. Switch parameter display Active? | Go to Step 39 | Go to Step 28 |
28 |
Does the test lamp illuminate? | Go to Step 29 | Go to Step 42 |
29 |
Does the 5 Bow Lowered Pos. Switch parameter display Active? | Go to Step 37 | Go to Step 31 |
30 | Test the signal circuit of the 5 bow raised switch for an open. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 39 |
31 | Test the signal circuit of the 5 bow lowered switch for an open. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 39 |
32 | Test the control circuit of the inoperative valve for a short to ground or an open. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 39 |
33 | Test the folding top cover pull down ajar signal circuit for an open. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 40 |
34 | Test the signal circuit of the folding top cover open switch for an open. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 39 |
35 | Test the signal circuit of the top closed switch for an open. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 39 |
36 | Test the folding top cover pull down ajar signal circuit for a short to ground. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 40 |
37 | Inspect for poor connections at the harness connector of the inoperative limit or position switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 44 |
38 | Inspect for poor connections at the harness connector of the folding top cover open limit switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 45 |
39 | Inspect for poor connections at the harness connector of the folding top control (FTC) module. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 46 |
40 | Inspect for poor connections at the harness connector of the body control module (BCM). Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 47 |
41 | Inspect for poor connections at the harness connector of the inoperative valve. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 49 | Go to Step 48 |
42 | Repair the open in the accessory voltage circuit of the inoperative limit or position switch. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 49 | -- |
43 | Repair the high resistance or open in the ground circuit of the inoperative valve. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 49 | -- |
44 | Replace the inoperative limit or position switch. Refer to Power Folding Top Limit Switches Replacements . Did you complete the replacement? | Go to Step 49 | -- |
45 |
Important: The folding top cover open limit switch is an internal part of the folding top cover hydraulic cylinder assembly that is not serviced separately. Replace the folding top cover open limit switch. Refer to Folding Top Cylinder Replacement . Did you complete the replacement? | Go to Step 49 | -- |
46 | Replace the FTC module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 49 | -- |
47 | Replace the BCM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 49 | -- |
48 | Replace the folding top pump, valve, and motor assembly. Refer to Folding Top Pump with Motor Replacement . Did you complete the replacement? | Go to Step 49 | -- |
49 |
Did you correct the condition? | System OK | Go to Step 2 |