Subject: | Power Folding Top Tech 2 Data Matrix Tables |
Models: | 2005-2008 Chevrolet Corvette |
with Power Folding Top (RPO CM7) |
The following diagnosis might be helpful if the vehicle exhibits the symptom(s) described in this PI.
The tables listed below are equipped with typical data values viewed when using the Tech 2 for diagnostics. Please use as a guide. As Tech 2 versions change, data can also change. When in doubt, compare values to a like vehicle.
Roof Closed to Roof Open | Roof Open to Roof Closed | |||
Roof Closed, Header Latched, Windows Up | Top Down, Tonneau Closed | |||
Header Latch Switch | Latched | Header Latch Switch | Unlatched | |
Power Pull Down Ajar Status | Closed | Power Pull Down Ajar Status | Closed | |
Tonneau Latch Switch | Closed | Tonneau Latch Switch | Closed | |
Tonneau Opened Limit Switch | Inactive | Tonneau Opened Limit Switch | Inactive | |
Top Closed Limit Switch | Active | Top Closed Limit Switch | Inactive | |
Top Open Limit Switch | Inactive | Top Open Limit Switch | Active | |
5th Bow Lowered Pos. Switch | Active | 5th Bow Lowered Pos. Switch | Inactive | |
5th Bow Raised Pos. Switch | Inactive | 5th Bow Raised Pos. Switch | Active | |
Luggage Barrier In Place | Yes | Luggage Barrier In Place | Yes | |
Window Position Status | OK | Window Position Status | Too High | |
Global Window Status | Enabled | Global Window Status | Enabled | |
Top Control Switch | Invalid | Top Control Switch | Invalid | |
Bows 1 & 5 Down, Header Unlatched | Top Stowed, Tonneau Open | |||
Header Latch Switch | Unlatched | Header Latch Switch | Unlatched | |
Power Pull Down Ajar Status | Closed | Power Pull Down Ajar Status | Ajar | |
Tonneau Latch Switch | Closed | Tonneau Latch Switch | Ajar | |
Tonneau Opened Limit Switch | Inactive | Tonneau Opened Limit Switch | Active | |
Top Closed Limit Switch | Active | Top Closed Limit Switch | Inactive | |
Top Open Limit Switch | Inactive | Top Open Limit Switch | Active | |
5th Bow Lowered Pos. Switch | Active | 5th Bow Lowered Pos. Switch | Inactive | |
5th Bow Raised Pos. Switch | Inactive | 5th Bow Raised Pos. Switch | Active | |
Luggage Barrier In Place | Yes | Luggage Barrier In Place | Yes | |
Window Position Status | Too High | Window Position Status | Too High | |
Global Window Status | Enabled | Global Window Status | Enabled | |
Top Control Switch | Invalid | Top Control Switch | Invalid | |
Bows 1 & 5 Up, Tonneau Closed | Top Extended, Tonneau Open | |||
Header Latch Switch | Unlatched | Header Latch Switch | Unlatched | |
Power Pull Down Ajar Status | Closed | Power Pull Down Ajar Status | Ajar | |
Tonneau Latch Switch | Closed | Tonneau Latch Switch | Ajar | |
Tonneau Opened Limit Switch | Inactive | Tonneau Opened Limit Switch | Active | |
Top Closed Limit Switch | Active | Top Closed Limit Switch | Active | |
Top Open Limit Switch | Inactive | Top Open Limit Switch | Inactive | |
5th Bow Lowered Pos. Switch | Inactive | 5th Bow Lowered Pos. Switch | Inactive | |
5th Bow Raised Pos. Switch | Active | 5th Bow Raised Pos. Switch | Active | |
Luggage Barrier In Place | Yes | Luggage Barrier In Place | Yes | |
Window Position Status | Too High | Window Position Status | Too High | |
Global Window Status | Enabled | Global Window Status | Enabled | |
Top Control Switch | Invalid | Top Control Switch | Invalid | |
Top Extended, Tonneau Open | Bows 1 & 5 Up, Tonneau Closed | |||
Header Latch Switch | Unlatched | Header Latch Switch | Unlatched | |
Power Pull Down Ajar Status | Ajar | Power Pull Down Ajar Status | Closed | |
Tonneau Latch Switch | Ajar | Tonneau Latch Switch | Closed | |
Tonneau Opened Limit Switch | Active | Tonneau Opened Limit Switch | Inactive | |
Top Closed Limit Switch | Active | Top Closed Limit Switch | Active | |
Top Open Limit Switch | Inactive | Top Open Limit Switch | Inactive | |
5th Bow Lowered Pos. Switch | Inactive | 5th Bow Lowered Pos. Switch | Inactive | |
5th Bow Raised Pos. Switch | Active | 5th Bow Raised Pos. Switch | Active | |
Luggage Barrier In Place | Yes | Luggage Barrier In Place | Yes | |
Window Position Status | Too High | Window Position Status | Too High | |
Global Window Status | Enabled | Global Window Status | Enabled | |
Top Control Switch | Invalid | Top Control Switch | Invalid | |
Top Stowed, Tonneau Open | Bows 1 & 5 Down, Header Unlatched | |||
Header Latch Switch | Unlatched | Header Latch Switch | Unlatched | |
Power Pull Down Ajar Status | Ajar | Power Pull Down Ajar Status | Closed | |
Tonneau Latch Switch | Ajar | Tonneau Latch Switch | Closed | |
Tonneau Opened Limit Switch | Active | Tonneau Opened Limit Switch | Inactive | |
Top Closed Limit Switch | Inactive | Top Closed Limit Switch | Active | |
Top Open Limit Switch | Active | Top Open Limit Switch | Inactive | |
5th Bow Lowered Pos. Switch | Inactive | 5th Bow Lowered Pos. Switch | Active | |
5th Bow Raised Pos. Switch | Active | 5th Bow Raised Pos. Switch | Inactive | |
Luggage Barrier In Place | Yes | Luggage Barrier In Place | Yes | |
Window Position Status | Too High | Window Position Status | Too High | |
Global Window Status | Enabled | Global Window Status | Enabled | |
Top Control Switch | Invalid | Top Control Switch | Invalid | |
Top Down, Tonneau Closed | Roof Closed, Header Latched, Windows Up | |||
Header Latch Switch | Unlatched | Header Latch Switch | Latched | |
Power Pull Down Ajar Status | Closed | Power Pull Down Ajar Status | Closed | |
Tonneau Latch Switch | Closed | Tonneau Latch Switch | Closed | |
Tonneau Opened Limit Switch | Inactive | Tonneau Opened Limit Switch | Inactive | |
Top Closed Limit Switch | Inactive | Top Closed Limit Switch | Active | |
Top Open Limit Switch | Active | Top Open Limit Switch | Inactive | |
5th Bow Lowered Pos. Switch | Inactive | 5th Bow Lowered Pos. Switch | Active | |
5th Bow Raised Pos. Switch | Active | 5th Bow Raised Pos. Switch | Inactive | |
Luggage Barrier In Place | Yes | Luggage Barrier In Place | Yes | |
Window Position Status | Too High | Window Position Status | OK | |
Global Window Status | Enabled | Global Window Status | Enabled | |
Top Control Switch | Invalid | Top Control Switch | Invalid |
Please follow this diagnostic or repair process thoroughly and complete each step. If the condition exhibited is resolved without completing every step, the remaining steps do not need to be performed.