Removal Procedure
- Remove the HVAC module. Refer to
HVAC Module Assembly Replacement
.
- Disconnect the HVAC module wiring harness retainer pin (2) from the HVAC module.
- Disconnect the wiring harness from the heater core cover wire harness retainer (1) and reposition the wiring harness aside.
- Disconnect the wiring harness from the heater core cover wire harness retainer (3) and reposition the wiring harness aside.
- Disconnect the discharge temperature management (DTM) sensor electrical connectors.
Important: Rotate the DTM sensor counter-clockwise to disengage the sensor from the air duct.
- Remove the DTM sensors.
- Remove the heater core cover screws.
- Remove the heater core cover.
Installation Procedure
- Install the heater core cover.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the heater core cover screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
Important: Rotate the DTM sensor clockwise to engage the sensor to the air duct.
- Install the DTM sensors.
- Connect the discharge temperature management (DTM) sensor electrical connectors.
- Connect the wiring harness to the heater core cover wire harness retainer (1).
- Connect the wiring harness to the heater core cover wire harness retainer (3).
- Connect the HVAC module wiring harness retainer pin (2) to the HVAC module.
- Install the HVAC module. Refer to
HVAC Module Assembly Replacement
.