Important: DO NOT reuse the gasket between the catalytic convertor and the exhaust manifold. Use new only.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the mounting nuts to 20 N·m (15 lb ft).
Callout | Component Name | ||||
---|---|---|---|---|---|
Notice: Refer to Fastener Notice in the Preface section. Fastener Tightening Specifications: Refer to Fastener Tightening Specifications . Preliminary Procedure
| |||||
1 | Intermediate Pipe Refer to Intermediate Pipe Replacement . | ||||
2 | Exhaust Pipe Seal | ||||
3 | Heated Oxygen Sensor (HO25) Bank 1 Sensor 1 Refer to Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 . | ||||
4 | Heated Oxygen Sensor (HO25) Bank 1 Sensor 2 Refer to Engine Identification . | ||||
5 | Catalytic Converter-to-Exhaust Manifold Nuts (Qty: 4) Tighten | ||||
6 | LH Catalytic Converter Tip | ||||
7 | Exhaust Manifold Pipe Gasket Tip |