Fuel Door Release System Components
• | Fuel door release actuator |
• | Fuel door release switch |
• | PRW/WNDWS/TRUNK/FUEL RELEASE circuit breaker (30 amp) |
The FUEL DR RELEASE relay switch and coil terminals are supplied with battery voltage at all times via the PRW/WNDWS/TRUNK/FUEL RELEASE circuit breaker from the BATT 1 fuse. When the fuel door release switch is activated, ground is applied to the
coil side of the FUEL DR RELEASE relay. This energizes the coil causing the switch contacts to close. With the switch contacts closed, battery voltage is supplied to the fuel door release actuator, opening the fuel door. Ground for the fuel door release switch
is supplied at G201 and the fuel door release actuator is provided ground at G301.