GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Hazard Switch Signal

1

1

1

--

Hazard Flasher Signal

2

2

2

--

Instrument Panel Lamps Control

3

3

3

--

Hazard Switch Ground

--

1

1

--

1. Hazard Lamps Malfunction

2. Hazard Lamp Indicators Malfunction

3. Interior Backlighting Malfunction

Circuit/System Description

The hazard flashers may be activated in any power mode. The hazard switch is permanently grounded through G201. When the hazard switch is placed in the ON position, ground is applied through the hazard switch signal circuit to the body control module (BCM). The BCM supplies battery voltage to all four turn signal lamps in an ON and OFF duty cycle. When the hazard switch is activated, the instrument panel cluster (IPC) hazard flasher signal circuit is grounded and the IPC request both turn signal indicators to be cycled ON and OFF.

Reference Information

Schematic Reference

Exterior Lights Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Exterior Lighting Systems Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

Hazard Lamps Malfunction

  1. Ignition OFF, disconnect the harness connector at the hazard switch.
  2. Ignition OFF, verify that a test lamp illuminates between B+ and the ground circuit terminal 2.
  3. If the test lamp does not illuminate, test the ground circuit for an open/high resistance.
  4. Ignition ON, verify the scan tool Hazard Lamp Switch parameter is Inactive.
  5. If not the specified value, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the BCM.
  6. Install a 3A fused jumper wire between the signal circuit terminal 1 and ground. Verify the scan tool Hazard Lamp Switch parameter is Active.
  7. If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.
  8. If all circuits test normal, test or replace the hazard switch.

Hazard Lamp Indicators Malfunction

  1. Ignition OFF, disconnect the harness connector at the hazard switch.
  2. Ignition OFF, verify that a test lamp illuminates between B+ and the ground circuit terminal 2.
  3. If the test lamp does not illuminate, test the ground circuit for an open/high resistance.
  4. Ignition ON, verify that a test lamp illuminates between the signal circuit terminal 4 and ground.
  5. If the test lamp does not illuminate, test the signal circuit for a short to ground or an open/high resistance.
  6. Install a 3A fused jumper wire between the signal circuit terminal 4 and ground. Verify the hazard lamp indicators are Illuminated.
  7. If the hazard flashers are not illuminated, test the signal circuit for a short to voltage. If the circuit tests normal, replace the IPC.
  8. If all circuits test normal, test or replace the hazard switch.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Hazard Warning Switch Replacement
    •  Control Module References for BCM or IPC replacement, setup, and programming