Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Locate the A/C coupling assembly locking tab access slots (1).
Important: When separating the A/C coupling assembly,
apply light pressure between the 2 halves of the coupling to prevent the locking
tabs from reengaging.
- Carefully insert a small flat-bladed screwdriver into the first locking
tab access slot and gently lift the locking tab to release the lock.
- Carefully insert a small flat-bladed screwdriver into the
second locking tab access slot and gently lift the locking tab to release the lock.
- Open and remove the A/C coupling assembly from the A/C refrigerant component.
Installation Procedure
Important: Inspect the A/C coupling assembly locking
tabs for damage or wear. Replace the A/C coupler assembly if any conditions exist.
- Install the A/C coupling assembly to the A/C refrigerant component.
Important: Ensure that the A/C coupling assembly is
latched securely to the A/C refrigerant component.
- Close the A/C coupling assembly.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using J 39400-A
.