Removal Procedure
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement .
- Disconnect the surge tank inlet hose assembly from the radiator support tabs.
- Remove the radiator support bolts.
Important: Note the position of the radiator support in relationship to the fan shroud. This must be reassembled correctly in order to retain the fan shroud.
- Remove the radiator support.
Installation Procedure
Important: Position the radiator support in the correct relationship to the fan shroud.
- Install the radiator support.
Notice: Refer to Fastener Notice in the Preface section.
- Install the radiator support bolts.
Tighten
Tighten the bolts to 9 N·m (80 lb in).
- Connect the surge tank inlet hose assembly to the radiator support tabs.
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement .