• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Backup Lamp Relay B+ | 1 | 1 | -- | -- |
Backup Lamp Relay Control | 1 | 1 | 1 | -- |
Backup Lamp Control | 1 | 1 | 1 | -- |
Backup Lamp - Left Ground | -- | 1 | 1 | -- |
Backup Lamp - Right Ground | -- | 1 | 1 | -- |
1. Backup Lamps Malfunction |
The underhood fuse block supplies battery voltage through the STOP/B/U/ LPS fuse to the coil and switch terminals of the BCK/UP LAMP Relay located in the body control module (BCM). When the transmission is placed in the REVERSE position, the transmission control module (TCM) sends a serial data message to the BCM. The message indicates that the gear selector is in the REVERSE position. The BCM grounds the back up lamp relay control circuit of the backup lamp relay. This energizes the backup lamp relay, closing the switch side contacts and provides battery voltage to the REVERSE LAMPS fuse through to the backup lamps. The backup lamps are permanently grounded at G302. With both power and ground the backup lamps illuminate. Once the driver moves the gear selector out of the REVERSE position, a message is sent by the TCM via serial data requesting the BCM to remove ground from the back up lamp relay control circuit. This opens the backup lamp relay switch contacts turning OFF the backup lamps.
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, test or replace the backup lamp relay. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the backup lamps do not illuminate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Backup Lamp Relay B+ | 1 | 1 | -- | -- |
Reverse Lamp Relay Control | 1 | 1 | 1 | -- |
Backup Lamp Relay Control | 1 | 1 | 1 | -- |
Backup Lamp Control | 1 | 1 | 1 | -- |
Reverse Switch Control | 1 | 1 | -- | -- |
Backup Lamp - Left Ground | -- | 1 | 1 | -- |
Backup Lamp - Right Ground | -- | 1 | 1 | -- |
1. Backup Lamps Malfunction |
The underhood fuse block supplies battery voltage through the STOP/B/U/ LPS fuse to the coil and switch terminals of the BCK/UP LAMP Relay located in the body control module (BCM). The BCM provides the normally open reverse switch with voltage. When the transmission is placed in the reverse position, the reverse switch closes providing a ground path through the reverse lamp relay control circuit to the BCM. The BCM then grounds the back up lamp relay control circuit of the backup lamp relay. This energizes the backup lamp relay, closing the switch side contacts and provides battery voltage to the REVERSE LAMPS fuse through to the backup lamps. The backup lamps are permanently grounded at G302. Once the driver moves the gear selector out of the REVERSE position, the reverse switch opens and the BCM removes ground from the backup lamp relay control circuit. This opens the backup lamp relay switch contacts turning OFF the backup lamps.
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, test or replace the backup lamp relay. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the backup lamps do not illuminate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the backup lamps do not activate, replace the backup lamp relay. |
⇒ | If greater than the specified range, test the control circuit for a short to voltage or an open/high resistance. If circuits test normal, replace the BCM. |
⇒ | If the test lamp illuminates, test the control circuit for a short to ground. |
⇒ | If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |