Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
- Disconnect the A/C refrigerant pressure sensor electrical connector.
- Remove the A/C refrigerant pressure sensor from the front evaporator line.
- Remove and discard the O-ring seal from the A/C refrigerant sensor port.
Installation Procedure
- Install a new O-ring seal onto the A/C refrigerant pressure sensor port. Refer to
O-Ring Replacement.
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C refrigerant pressure sensor to the front evaporator line and tighten to
5 N·m (44 lb in).
- Connect the A/C refrigerant pressure sensor electrical connector.
- Leak test the fittings of the component using
J 39400-A Halogen Leak Detector
.