Removal Procedure
- Remove the HVAC module. Refer to
HVAC Module Assembly Replacement.
- Disconnect the HVAC module wiring harness retainer pin (2) from the HVAC module.
- Disconnect the wiring harness from the heater core cover wire harness retainer (1) and reposition the wiring harness aside.
- Disconnect the wiring harness from the heater core cover wire harness retainer (3) and reposition the wiring harness aside.
- Disconnect the discharge temperature management (DTM) sensor electrical connectors.
Note: Rotate the DTM sensor counter-clockwise to disengage the sensor from the air duct.
- Remove the DTM sensors.
- Remove the heater core cover screws.
- Remove the heater core cover.
Installation Procedure
- Install the heater core cover.
Caution: Refer to Fastener Caution in the Preface section.
- Install the heater core cover screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
Note: Rotate the DTM sensor clockwise to engage the sensor to the air duct.
- Install the DTM sensors.
- Connect the discharge temperature management (DTM) sensor electrical connectors.
- Connect the wiring harness to the heater core cover wire harness retainer (1).
- Connect the wiring harness to the heater core cover wire harness retainer (3).
- Connect the HVAC module wiring harness retainer pin (2) to the HVAC module.
- Install the HVAC module. Refer to
HVAC Module Assembly Replacement.