Removal Procedure
- Remove the RH lower insulator panel. Refer to
Instrument Panel Insulator Panel Replacement.
- Disconnect the HVAC module wiring harness from the recirculation housing wire harness retainer.
- Remove the recirculation actuator mounting screws.
- Remove the recirculation actuator.
- Disconnect the electrical connector from the recirculation actuator.
Installation Procedure
- Connect the recirculation actuator electrical connector.
Caution: Refer to Fastener Caution in the Preface section.
- Install the recirculation actuator.
- Install the recirculation actuator mounting screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect the HVAC module wiring harness to the recirculation housing wire harness retainer.
- Install the RH lower insulator panel. Refer to
Instrument Panel Insulator Panel Replacement.