• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Defog Relay Switch B+ | 2 | 2 | -- | -- |
Rear Defog Relay Control | B0283 02 | B0283 05 | B0283 05 | -- |
Rear Window Defogger Grid Control | 2 | 2 | 1 | -- |
Rear Window Defogger Grid Ground | -- | 2 | 2 | -- |
1. Rear Defogger Always ON 2. Rear Defogger Inoperative |
When the rear window defogger switch is activated, the HVAC control module energizes the rear defog relay by grounding the rear defog relay control circuit. When the rear defog relay coil is energized, the switch contacts of the rear defog relay close allowing battery voltage to flow from the DEFOG fuse through the closed switch contacts and out the relay switched output to the rear window defogger grid.
Rear Window Defogger Description and Operation
⇒ | If the indicator does not turn ON or OFF with each switch press, replace the A14 HVAC control module. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the E18 rear window defogger grid does not activate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the E18 rear window defogger grid. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the A14 HVAC control module. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the A14 HVAC control module. |
⇒ | If the test lamp remains bright at the middle of the grid line, test for an open between the test point and the ground side of the grid. |
⇒ | If the test lamp remains off at the middle of the grid line, test for an open between the test point and the voltage supply side of the grid |
⇒ | If not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module replacement, setup, and programming |