The low speed cooling fan relay is controlled by the electronic control module (ECM). The ECM applies a ground to the low speed cooling fan relay to achieve low speed cooling fan operation. The ECM determines when to activate the low speed cooling fan relay depending on the coolant temperature and the A/C system high side pressure.
• | A short to battery voltage condition exists. |
• | This condition is present for more than 2 seconds. |
An intermittent problem may be caused by a poor connection, rubbed through wire insulation, or a broken wire inside the insulation.
Step | Action | Values | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Determine whether the Diagnostic System Check has been performed. Was the Diagnostic System Check performed? | -- | Go to Step 2 | |||||||
2 | Inspect the fuse F3. Is the fuse in good condition? | -- | Go to Step 4 | Go to Step 3 | ||||||
3 |
Is the repair complete? | -- | System OK | -- | ||||||
4 |
Does the voltage measure within the value specified? | 0 V | Go to Step 6 | Go to Step 7 | ||||||
5 |
Is the repair complete? | -- | System OK | -- | ||||||
6 | Measure the resistance between the high speed cooling fan relay terminals 86 and 85. Does the resistance measure near the value specified? | 0 ohms | Go to Step 7 | Go to Step 8 | ||||||
7 |
Is the repair complete? | -- | System OK | -- | ||||||
8 | Inspect for a short to voltage or open in the wiring between the following:
Is the problem found? | -- | Go to Step 9 | Go to Step 10 | ||||||
9 |
Is the repair complete? | -- | System OK | -- | ||||||
10 | Inspect for a poor connection at the ECM connector terminal A14. Is the problem found? | -- | Go to Step 11 | Go to Step 12 | ||||||
11 |
Is the repair complete? | -- | System OK | -- | ||||||
12 |
Is the repair complete? | -- | System OK | -- |