Circuit Description

The engine coolant temperature (ECT) sensor is a variable resistor that measures the temperature of the engine coolant. The engine control module (ECM) supplies 5 volts to the ECT signal circuit and supplies a ground to the low reference circuit. If the ECM detects an excessively low ECT signal voltage, which is a high temperature indication, this DTC sets.

The following table illustrates the difference between temperature, resistance, and voltage:

ECT

ECT Resistance

ECT Signal Voltage

Cold

High

High

Warm

Low

Low

DTC Descriptor

This diagnostic procedure supports the following DTC:

DTC P0117 Engine Coolant Temperature (ECT) Sensor Circuit Low Voltage

Conditions for Running the DTC

    • The ignition is ON or the engine is operating.
    • This DTC runs continuously once the above condition is met.

Conditions for Setting the DTC

The ECM detects that the ECT sensor is more than 129°C (264°F) for more than 50 seconds.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
    • The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

Conditions for Clearing the MIL/DTC

    • The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
    • A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
    • A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
    • Clear the MIL and the DTC with a scan tool.

Diagnostic Aids

    • An overheating condition may cause this DTC to set.
    • After starting the engine, the ECT sensor temperature should rise steadily, then stabilize after the thermostat opens.
    • Test the ECT sensor at various temperature levels in order to evaluate the possibility of a skewed sensor. A skewed sensor can result in a driveability condition.
    • If the vehicle has set overnight, the ECT sensor and the intake air temperature (IAT) sensor values should display within 3°C (5°F). Refer to Temperature Versus Resistance .
    • For an intermittent condition, refer to Intermittent Conditions .

Step

Action

Values

Yes

No

Schematic Reference: Engine Controls Schematics

Connect End View Reference: Engine Control Module Connector End Views or Engine Controls Connector End Views

1

Did you perform the Diagnostic System Check - Engine Controls?

--

Go to Step 2

Go to Diagnostic System Check - Engine Controls

2

Important: The cooling fans are commanded ON when certain DTCs are set.

  1. Turn ON the ignition, with the engine OFF.
  2. Observe the Engine Coolant Temperature (ECT) sensor parameter in the Engine Data 1 list with a scan tool.

Is the temperature at the specified value?

129°C (264°F)

Go to Step 4

Go to Step 3

3

  1. Observe the Freeze Frame/Failure Records for this DTC.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

--

Go to Step 4

Go to Diagnostic Aids

4

  1. Disconnect the ECT sensor.
  2. Observe the ECT sensor parameter with a scan tool.

Is the temperature at the specified value?

-39°C (-38°F)

Go to Step 6

Go to Step 5

5

Test the signal circuit of the ECT sensor for a short to ground or for a short to the low reference circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 10

Go to Step 8

6

Test for shorted terminals and for poor connections at the ECT sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 10

Go to Step 8

7

Test for shorted terminals and for poor connections at the engine control module (ECM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 10

Go to Step 9

8

Replace the ECT sensor. Refer to Engine Coolant Temperature Sensor Replacement .

Did you complete the replacement?

--

Go to Step 10

--

9

Replace the ECM. Refer to Engine Control Module Replacement .

Did you complete the replacement?

--

Go to Step 10

--

10

  1. Clear the DTCs with a scan tool.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

--

Go to Step 2

Go to Step 11

11

Observe the Capture Info with a scan tool.

Are there any DTCs that have not been diagnosed?

--

Go to Diagnostic Trouble Code (DTC) List

System OK