Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the electrical connector.
- Remove the bolt and the horn.
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the horn with the bolt.
Tighten
Tighten the horn bolt to 20 N·m (15 lb ft).
- Connect the electrical connector.