Removal Procedure

    Caution: Refer to Battery Disconnect Caution in the Preface section.


    Object Number: 1256113  Size: SH
  1. Disconnect the negative battery cable.
  2. Remove the I/P storage compartment. Refer to Instrument Panel Storage Compartment Replacement in Instrument Panel, Gages, and Console.
  3. Remove the actuating rod by snapping the rod out of the lever with needle-nose pliers.
  4. Remove the actuating lever.
  5. Disconnect the electrical connector.

  6. Object Number: 1256114  Size: SH
  7. Remove the motor retaining screws.
  8. Remove the motor.

Installation Procedure


    Object Number: 1256114  Size: SH
  1. Install the motor.
  2. Install the motor retaining bolts and tighten.

  3. Object Number: 1256113  Size: SH
  4. Install the actuating lever.
  5. Install the actuating rod.
  6. Connect the electrical connector.
  7. Remove the I/P storage compartment. Refer to Instrument Panel Storage Compartment Replacement in Instrument Panel, Gages, and Console.
  8. Connect the negative battery cable.