When the ignition switch is turned to ON, the sensing and diagnostic module (SDM) will perform a turn-on test to diagnose critical malfunctions within the SDM itself.
Upon passing this test, ignition and deployment loop voltages are measured to ensure that they are within their normal voltage ranges. The SDM monitors the voltages at the driver low and the passenger low to detect shorts to ground or voltage in the deploy loops.
The SDM checks the wiring connection to the passenger air bag module by letting the infinitesimal current flow through the internal circuit and verify the resistance.
The resistance of the driver belt pretensioner deploy loop is over 3.1 ohms.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Caution: Refer to Sensing and Diagnostic Module Voltage after Ignition is Turned Off Caution in the Preface section. Caution: Refer to Sensing and Diagnostic Module Handling Caution in the Preface section. | ||||
1 | Did you perform the Diagnostic System Check - SIR? | -- | Go to Step 2 | |
2 |
Is the resistance as specified? | 10k ohms | Go to Step 3 | Go to Step 5 |
3 |
Is DTC 009 still shown as a current fault? | -- | Go to Step 4 | System OK |
4 | Replace the driver seat belt pretensioner. Refer to Front Seat Belt Replacement in seat belts. Did you complete the repair? | -- | -- | |
5 | Replace the supplemental inflatable restraints (SIR) wiring harness. Did you complete the repair? | -- | -- |