When the ignition switch is turned to ON, the sensing and diagnostic module (SDM) will perform a turn-on test to diagnose critical malfunctions within the SDM itself.
These test ignition and deployment loop voltages are measured to ensure that they are within their normal voltage ranges. The SDM monitors the voltages at the driver low and the passenger low to detect shorts to ground or voltage in the deploy loops.
The SDM inspects the wiring connection to the passenger air bag module by letting the perpetual current flow through the internal circuit and verify the resistance.
• | The resistance of the passenger air bag deployment loop is lower than 1.4 ohms. |
• | The shorting bar is damaged and the SDM must be replaced. |
Step | Action | Values | Yes | No |
---|---|---|---|---|
Caution: Refer to Sensing and Diagnostic Module Handling Caution in the Preface section. Caution: Refer to SRS Sensing and Diagnostic Module Handling Caution in the Preface section. | ||||
1 |
Has the SDM discharged? | -- | Go to Step 2 | -- |
2 | Visually inspect the connector and the wiring of the passenger air bag. Is the wiring damaged? | -- | Go to Step 5 | Go to Step 3 |
3 |
Is the resistance equal to the specified value? | ∞ ohms | Go to Step 4 | Go to Step 5 |
4 |
Is the DTC removed? | -- | Go to Step 6 | |
5 | Replace the air bag wiring. Is the replacement complete? | -- | -- | |
6 | Replace the passenger air bag module. Refer to Inflatable Restraint Instrument Panel Module Replacement . Is the replacement complete? | -- | -- |