This code will set if the output of the sun sensor indicates a probable short circuit or an open in the sensor or the associated wiring harness, or a malfunction of the automatic temperature controller (ATC).
Step | Action | Values | Yes | No |
---|---|---|---|---|
1 |
Is there any sign of damage in the wiring or connector or does the resistance equal the value specified? | 0 ohms | Go to Step 2 | Go to Step 3 |
2 | Repair the damaged wiring on the connector, or replace the sun sensor as required. Is the repair complete? | -- | System OK | -- |
3 |
Is the voltage less than the specified value? | 4 V | Go to Step 7 | Go to Step 4 |
4 | Inspect the terminals on the sun sensor connector. Is any problem found with the connector? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the connector terminals or replace the sun sensor to ATC as required. Is the repair complete? | -- | System OK | -- |
6 |
Does this display indicate the continuing presence of a code 5 condition? | -- | Go to Step 9 | System OK |
7 |
Is the voltage less than the specified value? | 4 V | Go to Step 9 | Go to Step 8 |
8 |
Is the repair complete? | -- | System OK | -- |
9 | Replace the ATC controller. Refer to Heater and Air Conditioning Control Replacement . Is the repair complete? | -- | System OK | -- |