Step | Action | Values | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 |
Does the resistance equal the specified value? | 0 ohms | Go to Step 2 | Go to Step 6 | ||||
2 | Measure the resistance in the circuit from terminal 1 of the power module control unit to terminal B12 of the ATC controller. Does the resistance equal the specified value? | 0 ohms | Go to Step 3 | Go to Step 6 | ||||
3 |
Do the voltages measured match the specified ranges? | Speed 1:8.3-9.3 V Speed 2: 6.3-7.3 V Speed 3: 3.9-4.9 V Speed 4: 2.2-3.2 V Speed 5: 0-0.5 V | Go to Step 4 | Go to Step 5 | ||||
4 | Replace the ATC controller. Refer to Heater and Air Conditioning Control Replacement . Is the repair complete? | -- | System OK | -- | ||||
5 | Measure the resistance in circuit PNK between terminal 6 of the power transistor and the blower motor terminal 2. Does the resistance equal the specified value? | 0 ohms | Go to Step 7 | Go to Step 6 | ||||
6 | Repair or replace the wiring harness for the circuit PNK. Is the repair complete? | -- | System OK | -- | ||||
7 | Inspect the wiring harness of the motor and power supply.
Is there any problem in the wiring, the relay, or the fuse? | -- | Go to Step 9 | Go to Step 8 | ||||
8 | Replace the power transistor. Refer to Blower Motor Control Module Replacement . Is the repair complete? | -- | System OK | -- | ||||
9 | Repair or replace the wiring harness, the relay, or the fuse as required. Is the repair complete? | -- | System OK | -- |