The number below refers to the step number on the diagnostic table.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Caution: Do not connect a jumper cable directly to the negative terminal of a discharged battery to prevent sparking and possible explosion of battery gases. | ||||
Does the bulb pass the visual and physical check? | -- | Go to Step 3 | Go to Step 2 | |
2 | Replace the bulb. Is the repair complete? | -- | System OK | -- |
3 |
Is fuse F13 open? | -- | Go to Step 4 | Go to Step 5 |
4 |
Is the repair complete? | -- | System OK | -- |
5 | Measure the voltage at fuse F13. Does the voltage at fuse F13 measure within the specified range? | 11-14 V | Go to Step 7 | Go to Step 6 |
6 | Repair the open circuit between the battery and fuse F8. Is the repair complete? | -- | System OK | -- |
7 |
Does the voltage at terminal 1 of the glove box lamp measure within the specified range? | 11-14 V | Go to Step 8 | Go to Step 9 |
8 | Repair the open circuit between fuse F13 and the glove box lamp. Is the repair complete? | -- | System OK | -- |
9 |
Does the voltage at terminal 1 of the glove box lamp switch measure within the specified range? | 11-14 V | Go to Step 11 | Go to Step 10 |
10 | Repair the open circuit between the glove box lamp and the glove box lamp switch. Is the repair complete? | -- | System OK | -- |
11 | Use an ohmmeter to measure the resistance between ground and terminal 2 of the glove box lamp switch connector on the harness side. Is the resistance equal to the specified value? | 0 ohms | Go to Step 12 | Go to Step 13 |
12 | Replace the glove box lamp switch. Is the repair complete? | -- | System OK | -- |
13 | Repair the ground circuit for the glove box lamp switch. Is the repair complete? | -- | System OK | -- |