Yazaki Connectors 16-Way
Special Tools
J-38125
Terminal Repair Kit
Removal Procedure
- While depressing the lock, pull the two connector halves apart.
Note: The TPA is fragile and may break if not done carefully.
- Use a small flat-blade tool to very carefully push the terminal position assurance (TPA) towards the face of the connector on both sides of the connector.
- View of the male half of the connector with female terminals.
- View of the female half of the connector with male terminals.
- Use the J 38125-215 tool to release the terminals by inserting the tool into the terminal release cavity. See the release tool cross reference in the Reference Guide of the
J-38125
to ensure
that the correct release tool is used.
- View of the female half of the connector with male terminals.
- View of the male half of the connector with female terminals.
- While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.
Repair Procedure
Use the appropriate terminal and follow the instructions in the
J-38125
.
Location of the terminal in the repair tray and the proper crimp tool can be found in the appropriate connector end view.