Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Measure the voltage between terminal 4 and ground of the mode motor and the HTR/DEF motor. Is the voltage within the specified value for both motors? | 11-14 V | Go to Step 3 | Go to Step 2 |
2 |
Is the repair complete? | -- | System OK | -- |
3 |
Are the voltages within the Motor Control table? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the motor that does not operate properly. Is the repair complete? | -- | System OK | -- |
5 |
Are the voltages within the Motor Control table? | -- | Go to Step 6 | Go to Step 7 |
6 |
Is the repair complete? | -- | System OK | -- |
7 | Inspect the connector at the controller. Is there a defective terminal? | -- | Go to Step 8 | Go to Step 9 |
8 | Repair or replace the terminal. Is the repair complete? | -- | System OK | -- |