Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Inspect the other instrumentation lights. Are any other instrumentation lights off? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified value? | 11-14 V | Go to Step 4 | Go to Step 3 |
3 | Repair the wiring harness between the splice S204 and controller connector terminal A4 or between splice S204 and controller connector terminal A3. Is the repair complete? | -- | System OK | -- |
4 | Inspect the illumination lamps. Are any illumination lamps burned out? | -- | Go to Step 5 | System OK |
5 | Replace the burned out illumination lamp. Is the repair complete? | -- | System OK | -- |