Step | Action | Values | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Verify the customer's complaint. Are the customer's concerns verified? | -- | Go to Step 2 | System OK | ||||||||
2 | Turn the blower ON. Does the blower run at any speed? | -- | Go to Step 14 | Go to Step 3 | ||||||||
3 |
Is the voltage within the specified range? | 11-14 V | Go to Step 4 | Go to Step 5 | ||||||||
4 | Replace the blower motor. Did you complete the replacement? | -- | System OK | -- | ||||||||
5 | Inspect fuse EF6 in the engine fuse block. Is the fuse open? | -- | Go to Step 6 | Go to Step 7 | ||||||||
6 |
Did you complete the repair? | -- | System OK | -- | ||||||||
7 |
Is the ground OK? | -- | Go to Step 9 | Go to Step 8 | ||||||||
8 | Repair the blower motor ground. Is the repair complete? | -- | System OK | -- | ||||||||
9 | Inspect the motor connector with a 12-volt test light. Does the test light come on? | -- | Go to Step 10 | Go to Step 11 | ||||||||
10 | Repair the open in the feed wire from the resistor block to the blower motor. Did you complete the repair? | -- | System OK | -- | ||||||||
11 | Use the 12-volt test light to inspect the power feed terminal on the blower speed switch. Does the light come on? | -- | Go to Step 12 | Go to Step 13 | ||||||||
12 | Replace the blower speed switch. Did you complete the replacement? | -- | System OK | -- | ||||||||
13 | Repair the open in the power wire from the blower speed switch to the fuse panel. Did you complete the repair? | -- | System OK | -- | ||||||||
14 | Turn the blower on speed 4. Does the blower fail to operate at speed 4? | -- | Go to Step 15 | Go to Step 21 | ||||||||
15 | Inspect fuse F7 in the I/P fuse block. Is the fuse open? | -- | Go to Step 16 | Go to Step 17 | ||||||||
16 |
Did you complete the repair? | -- | System OK | -- | ||||||||
17 |
Is the voltage between the specified value? | 11-14 V | Go to Step 18 | Go to Step 19 | ||||||||
18 | Replace the blower speed switch. Did you complete the replacement? | -- | System OK | -- | ||||||||
19 |
Is the repair complete? | -- | System OK | Go to Step 20 | ||||||||
20 | Replace the blower HI relay. Did you complete the replacement? | -- | System OK | -- | ||||||||
21 |
Does the test light illuminate on all terminals? | -- | Go to Step 23 | Go to Step 22 | ||||||||
22 | Replace the resistor block. Did you complete the replacement? | -- | System OK | -- | ||||||||
23 |
Does the lamp illuminate on all 3 wires? | -- | Go to Step 25 | Go to Step 24 | ||||||||
24 | Replace the blower speed switch. Did you complete the replacement? | -- | System OK | -- | ||||||||
25 | Repair the open in the affected wire. Did you complete the repair? | -- | System OK | -- |