Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 160-220 kPa (23-32 psi) | 1267-1576 kPa (185-230 psi) | 9°C (48°F) |
19-24°C (66-75°F) | Less than 40% | 178-246 kPa (26-35 psi) | 1439-1781 kPa (210-260 psi) | 11°C (52°F) |
Greater than 40% | 178-257 kPa (26-37 psi) | 1471-1815 kPa (215-265 psi) | 13°C (55°F) | |
25-29°C (76-85°F) | Less than 35% | 199-262 kPa (29-38 psi) | 1581-2021 kPa (231-295 psi) | 14°C (58°F) |
35-60% | 200-282 kPa (29-41 psi) | 1551-2062 kPa (226-301 psi) | 16°C (61°F) | |
Greater than 60% | 203-270 kPa (30-39 psi) | 1336-1987 kPa (195-290 psi) | 16°C (61°F) | |
30-35°C (86-95°F) | Less than 30% | 216-282 kPa (31-41 psi) | 1439-1790 kPa (210-261 psi) | 16°C (61°F) |
30-50% | 216-292 kPa (31-43 psi) | 1473-1750 kPa (215-255 psi) | 17°C (63°F) | |
Greater than 50% | 206-306 kPa (30-45 psi) | 1473-1690 kPa (215-247 psi) | 19°C (66°F) | |
36-41°C (96-105°F) | Less than 20% | 206-298 kPa (30-44 psi) | 1576-1879 kPa (230-274 psi) | 18°C (64°F) |
20-40% | 233-310 kPa (34-45 psi) | 1610-1839 kPa (235-269 psi) | 19°C (66°F) | |
Greater than 40% | 246-363 kPa (35-53 psi) | 1670-1952 kPa (244-285 psi) | 23°C (74°F) | |
42-46°C (106-115°F) | Less than 20% | 249-336 kPa (36-49 psi) | 1799-2055 kPa (263-300 psi) | 22°C (71°F) |
Greater than 20% | 253-349 kPa (37-51 psi) | 1780-2055 kPa (260-300 psi) | 23°C (74°F) | |
47-49°C (116-120°F) | Below 30% | 270-349 kPa (39-51 psi) | 1839-2124 kPa (269-310 psi) | 23°C (74°F) |