The air delivery description and operation is divided into 4 areas:

    • HVAC control components
    • Air speed
    • Air delivery
    • Recirculation operation

HVAC Control Components

HVAC Control Module

The HVAC control module is a non-class 2 device that interfaces between the operator and the HVAC system to maintain air temperature and distribution settings. The battery positive and ignition 3 voltage circuits provide power to the control module. The control module supports the following features:

Feature

Availability

After Blow

No

Purge

No

Personalization

No

Actuator Calibration

Yes

Mode Actuators - Defrost, Panel and Floor

The mode actuators are 5-wire bi-directional electric motors that incorporate a feedback potentiometer. Low reference, 5-volt reference, position signal, and 2 control circuits enable the actuators to operate. The control circuits use either a 0 or 12-volt value to coordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In order to move the actuator, the HVAC control module grounds one of the control circuits while providing the other with 12 volts. The HVAC control module reverses the polarity of the control circuits to move the actuator in the opposite direction. When the actuator shaft rotates, the potentiometer's adjustable contact changes the door position signal between 0-5 volts.

The HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a 0-255 count range. When the module sets a commanded, or targeted, value, one of the control circuits is grounded. As the actuator shaft rotates the changing position signal is sent to the module. Once the position signal and the commanded value are the same, the module removes power from both control circuits.

Air Speed

The HVAC control assembly applies ground to the blower motor control circuit that corresponds to the selected blower speed. The resistors and the blower motor are in a series circuit. The following list represents the number of resistors in series with the blower motor per particular speed request:

    • Low speed--3 resistors
    • Medium 1 speed--2 resistors
    • Medium 2 speed--1 resistor

When the operator requests High speed, the HVAC control assembly applies ground directly to the blower motor through the high blower motor control circuit. The resistor card has a fusible link which, if blown, will require that the card be replaced.

Air Delivery

The mode actuator drives a cam that moves the floor/defrost and panel doors and controls air delivery. The HVAC control module controls this actuator in order to distribute airflow to desired outlets.

A/C mode will be requested when:

    • A/C mode is OFF and A/C push button has been pressed once, or
    • blend or defrost mode is selected (detents 9-13), and
    • blower switch is in position 1,2,3 or 4

Recirculation mode shall only be available/selectable in panel and bi-level mode (detents 1-5).

The flow of air during the various modes of operation is as follows:

    • Panel--All air from Instrument panel (I/P) outlets
    • Bi-Level--I/P and all floor outlets
    • Floor--All floor outlets, and with bleed to side window (SWD) outlets and defrost outlets
    • Mix-Blend--All Floor outlets and defrost outlet, with bleed to SWD outlets
    • Defrost--Defrost outlet and SWD outlets, with bleed to all floor outlets

Recirculation Operation

The recirculation actuator is a 2-wire bi-directional electric motor. Two control circuits enable the actuator to operate. The control circuits use either ground or a 12-volt value to coordinate the actuator movement. The HVAC control assembly reverses the polarity of the control circuits to move the actuator in the opposite direction. The recirculation operation can function with blower motor in either the ON or OFF position. The A/C compressor automatically comes on when recirculation is selected. recirculation is not available in defrost, mix-blend or floor mode. The recirculation LED may still be ON while the air inlet door is in the outside air position.