Removal Procedure
- Remove the negative battery cable. Refer to
Battery Negative Cable Replacement.
- Mark the location of the battery current sensor on the battery cable with tape for reference during installation.
- Remove the tape securing the battery current sensor to the negative battery cable.
- Mark the location of the negative battery cable clips and remove the clip from the cable.
- Squeeze the negative battery cable branches together.
Important: Note the orientation of the battery current sensor prior to removal.
- Slide the battery current sensor (1) off of the negative battery cable.
Installation Procedure
- Squeeze the negative battery cable branches together.
Important: Ensure the battery current sensor is installed in the correct direction and location on the negative battery cable.
- Slide the NEW battery current sensor (1) up onto the negative battery cable to the location previously marked during removal.
- Wrap electrical tape around the battery current sensor leg in order to secure the sensor to the negative battery cable.
- Install the negative battery cable clip to the cable to the locations previously marked during removal.
- Install the negative battery cable. Refer to
Battery Negative Cable Replacement.