• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
5-Volt Reference | B1516 08 | B1516 08 | -- | -- |
Signal | B1516 08 | B1516 08 | B1516 08 | B1516 08, B1516 66 |
Low Reference | -- | B1516 08 | -- | -- |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Ignition ON, engine OFF. Headlamps, HVAC, and all accessories Off. Parameter Normal Range: -5 amps to -10 amps | |||
5-Volt Reference | -59.9 amps | -59.9 amps | -- |
Signal | -59.9 amps | 59.9 amps | 59.9 amps |
Low Reference | -- | 59.9 amps | -- |
The battery current sensor is a 3-wire hall effect current sensor. The body control module (BCM) supplies 5 volts and ground to the battery current sensor. The battery current sensor measures the amount of current flowing to or from the battery, and supplies a pulse width modulation (PWM) signal to the BCM. The normal operating range of the current sensor is 5-95 percent duty cycle. The BCM monitors the battery current signal, and sets DTC B1516 08 if the signal is outside the range of 4-96 percent duty cycle. The BCM also monitors the current polarity, and sets DTC B1516 66 if reverse polarity is detected.
The BCM is awake.
• | The BCM is awake. |
• | The hood, doors, and rear hatch are closed. |
• | The engine is not running. |
• | DTC B1516 08 has run and passed. |
The battery current sensor signal is less than 4 percent or greater than 96 percent duty cycle for 2 minutes.
The battery current is positive for 2 minutes.
The regulated voltage control (RVC) is disabled.
The DTC passes when the battery current returns to the normal range for 15 seconds.
DTC B1516 66 may set if a battery charger is used.
Starting and Charging Schematics
Charging System Description and Operation
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. |
⇒ | If less than the specified range , test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, then replace the BCM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, then replace the BCM. |
⇒ | If less than the specified range, test the signal circuit terminal C for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the battery current sensor is not installed correctly, remove and reinstall the sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming. |